This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.

SEM ICU 10 on Husaberg FC600 2000

Joined May 2010
2 Posts | 0+
HI. I'm from Poland.
Have problem with my Husaberg FC600 2000. I bought it dismantled in box. Had gearbox damaged. I repaired this machine. i try to start this machine and it has not spark on the plug. I check the stator resistance and it is ok.
1. How to check this ICU-10 coil?? It has map switch on the bar.
2. i try to start it with 1994 TM red coil, when i kick it hard - husaberg kick my leg as a f..ck. I dont know why. maybe i kick it wrong?? maybe this tm coil doesnt fit to this motor?
i check the ignition marks and it is on the left mark.
3. Which position of MAP switch is good to kickstart?? Hi or LO??

Best regards from Poland.
PS. It's my first Berg
 
hello and welcome to UHE fella

OK, you probably still have a SEM failure because even though they show 2.7 or even 2.8 they are kaputt! fin, finito.

red to black wants to be a minimum of 2.8 and even then 2.82, 2.84 and still they can be kaputt!

i never found any difference between 'Hi' and 'Lo'.

if and when you start the bike, try to put a timing light on the ignition which should be 6 degrees before top dead centre using the new marks you can see in the doc under 'electrical'.

good luck

regards

Taffy
 
OK, you probably still have a SEM failure because even though they show 2.7 or even 2.8 they are kaputt! fin, finito.

red to black wants to be a minimum of 2.8 and even then 2.82, 2.84 and still they can be kaputt!
but i replace ICU 10 coil the older one from 94 Husaberg fe 600 Red coil - one kick and there was spark on the plug.

Next i try to kickstart the motor with this 94 red coil and it kick me back several times.
 